Acrel AKH-0.66/II Series Current Transformer

Acrel AKH-0.66/II Series Current Transformer

 

● Clamshell design

● Beautiful shape easy wiring

● High accuracy

● Suitable for busbar or cable

Certificate: CE

微信图片_20241113104505_副本微信图片_20241113104458_副本


Product Detail

Technical Parameters

Download

Product Tags

Acrel AKH-0.66/II Series Current Transformer

General

Acrel AKH-0.66/II Series Current Transformer Horizontal square hole type, they can pass through 1-6 bar bus and also pass through multiple cables. They are generally used with electrical measuring instruments, widely used in electrical sets.

The measuring range of primary current is 100-6300A, and the secondary output is 5A or 1A. The measuring range is 5-120% of the rated value.

Diagram of AKH-0.66/II Series Current Transformer

Spec. and size akh-0.66-ii-series-current-transformer
Type Outline size Through size Mounting size Tolerance
(mm)
W H D a e M N P Q Φ
30II 62 98 45 32 32 28 57.5 36.5 29.5 5 ±1
40II 79 103 45 43 31.5 48 57.5 43 28.5 5
50II 87 113 45 52 32 30 57.5 55 36 5
60II 102 125 45 61 33 42 57.5 50.5 41.5 5
60×50II 102 142 45 62 51.5 42 57.5 51.5 39 5
80II 117 119 45 82 32 60 57.5 48 39 5
80×50II 120 141 45 82 52 60 57.5 49.5 39.5 5
100II 145 125 45 103 35 80 57.5 49.5 40.5 5
100×50II 145 155 50 103 55 80 70.5 57.5 42.5 5
100×80II 152 190 55 104 85 80 70.5 59.5 45.5 5
120×50II 174 168 50 122 53 80 70.5 63 52 5
120×80II 160 193 60 122 72 54 70.5 68 53 5
130×50II 176 160 50 135 55 85 70.5 59.5 45.5 5
150×50II 210 176 55 155 55 103 70.5 70.5 50.5 5
180×50II 240 181 60 185 55 40/40/40 83 70.5 55.5 5
200×50II 247 172 55 205 60 102 83 63 49 5
220×50II 280 190 60 225 55 65/55/65 83 73.5 61.5 5
260×50II 320.5 191 60 264.5 54.5 65/55/65 83 75.5 61 5
170×100II 227 230 60 172 105 103 83 70 55 5
260×100II 308 226 63 265 103 181 83 69 54 5

 

AKH-0.66/II Series Current Transformer can be installed in three ways: A-type straight plate is fixed, C-type single plate pressure plate is fixed, and D-type Double plate pressing plate fixation. Note that when the current transformer is in use, the secondary open circuit shall not be allowed, and the secondary outlet S2 shall be grounded.

diagram-of-akh-0.66-ii-series-current-transformer

Benefits of AKH-0.66/II Series Current Transformer

 Clamshell design easy to view wiring

• Beautiful shape easy wiring

• High accurancy with CE standard

 Suitable for busbar or cable

Use of AKH-0.66/II Series Current Transformer

• Used for internal measurement in industrial and mining enterprises

• Measure 1-6 busbar or cable in the power distribution room

• Convert the large current at the primary side to 5A or 1A, connect to energy meter

• When using a current transformer, the secondary open circuit is not allowed, and the secondary outlet S2 should be grounded


  • Previous:
  • Next:

  • Acrel AKH-0.66/II Series Current Transformer

    Technical Parameters

    Shape Specification Rated current ratio (A) Accuracy degree and corresponding rated load(VA) Straight- through tums Bus spec(mm)/number Installation
    0.2
    0.5
    1
     30II_副本 30II 100/5(1) 1.5
    1
    30×10/1-2 A, C
    150/5(1) 1.5
    1
    200/5(1) 2.5
    1
    250/5(1) 3.75
    1
    300-450/5(1) 5
    1
    500/5(1) 10
    1
    600/5 10
    1
     40II_副本 40II 100/5(1) 1.5
    1
    40×10/
    1-2
    A, C
    150/5(1) 2.5
    1
    200/5(1) 2.5
    1
    250/5(1) 3.75
    1
    300-450/5(1) 5
    1
    500-800/5(1) 10
    1
    1000/5(1) 10
    1
    50II_副本 50II 150 2.5
    1
    50×10/1-2 A, C
    200-250/5(1) 2.5
    1
    300-450/5(1) 5
    1
    500-800/5(1) 10
    1
    1000-1250/5(1) 10
    1
    1500/5(1) 20
    1
    60II_副本 60II 200-250/5(1) 2.5
    1
    60×10/
    1-2
    C
    300-450/5(1) 5
    1
    500-800/5(1) 10
    1
    1000-1250/5(1) 10
    1
    1500-2000/5(1) 20
    1
    2500/5(1) 30
    1
     60X50II_副本 60X50II 200-250/5(1) 2.5
    1
    60×10/
    1-3
    D
    300-450/5(1) 5
    1
    500-800/5(1) 10
    1
    1000-1250/5(1) 10
    1
    1500-2000/5(1) 20
    1
    2500/5(1) 30
    1
    80II_副本 80II 200-250/5(1) 2.5
    1
    80×10/
    1-2
    300-450/5(1) 5
    1
    500-800/5(1) 10
    1
    1000-1250/5(1) 10
    1
    1500-2000/5(1) 20
    1
    2500-3000/5(1) 30
    1
    80X50II_副本 80×50II 200-250/5(1) 2.5
    1
    80×10/
    1-3
    300-450/5(1) 5 1
    500-800/5(1) 10 1
    1000-1250/5(1) 10 1
    1500-2000/5(1) 20 1
    2500-3000/5(1) 30 1
    100II_副本 100II 300-450/5(1) 5 1 100×10/
    1-2
    D
    500-800/5(1) 10 1
    1000-1250/5(1) 10 1
    1500-2000/5(1) 20 1
    2500-4000/5(1) 30 1
     akh-0.66-ii-series-current-transformer-100×50ii 100×50II 300-450/5(1) 50 1 100×10/
    1-3
    500-800/5(1) 10 1
    1000-1250/5(1) 10 1
    1500-2000/5(1) 20
    1
    2500-4000/5(1) 30
    1
    100X80II_副本 100×80II 600-800/5(1) 10
    1
    100×10/
    1-4
    1000-1250/5(1) 10 1
    1500-2000/5(1) 20 1
    2500-4000/5(1) 30 1
     120X50II_副本 120×50II 500-800/5(1) 10 1 120×10/
    1-3
    1000-1250/5(1) 10 1
    1500-2000/5(1) 20 1
    2500-5000/5(1) 30 1
     130X50II_副本 130×50II 600-800/5(1) 10 1 125×10/1-3
    130×10/1-3
    60×10/2-6
    D
    1000-1250/5(1) 10 1
    1500-2000/5(1) 20 1
    2500-5000/5(1) 30 1
    akh-0.66-ii-series-current-transformer-120×80ii 120×80II
    150×50II
    1000-1250/5(1) 10 1 120×10/
    1-4
    1500-2000/5(1) 20 1
    2500-5000/5(1) 30
    1
    170×100II 1500-2000/5(1) 15
    1
    170×10/1-3
    100×10/3-6
    2500-5000/5(1) 30
    1
    180×50II 1200-2000/5(1) 10
    1
    180×10/1-3
    2500-5000/5(1) 30
    1
     akh-0.66-ii-series-current-transformer-200×50ii 200×50II
    220×50II
    260×50II
    1500-2000/5(1) 20
    1
    200×10/1-3
    100×10/4-6
    2500-5000/5(1) 30
    1
    260×100II 1200-1500/5(1) 10 1 250×10/2-5
    125×10/4-10
    1500-2000/5(1) 20 1
    2500-6300/5(1) 30 1

     

     

     

    AKH-0.66 CT and Hall Effect Sensor CE-LVD Certificate AT78251SC205023

    CE证书-PD_0478_2024