Acrel AKH-0.66/III Series Current Transformer

Acrel AKH-0.66/III Series Current Transformer

 

● Clamshell design

● Beautiful shape easy wiring

● High accuracy

● Suitable for busbar or cable

Certificate: CE

微信图片_20241113104505_副本微信图片_20241113104458_副本


Product Detail

Technical Parameters

Download

Product Tags

Acrel AKH-0.66/III Series Current Transformer

General

Acrel AKH-0.66/III Series Current Transformer Clamshell design, beautiful appearance, convenient wiring. Cover material selection with transparent polycarbonate, you can clearly see the secondary lead connection.

Vertical side Pass type, can pass through 1-3 busbar, not only has the characteristics of type I, II, And can be used for power supply system metering, and can be matched with current relay Used for protection.

Diagram of AKH-0.66/III Series Current Transformer

Spec. and size akh-0.66-iii-series-current-transformer
Type Outline size Through size Mounting size Tolerance
(mm)
W H D Φ a e M N
60III 117 147 55 / 52 62 / / ±1
80III 117 167 55 / 52 82 / /
100III 120 190 55 / 52 102 / /
130III 125 224 55 / 52 132 / /

 

AKH-0.66/III Series Current Transformer is installed in E-Type: Fixed by generatrix. Note that when the current transformer is in use, the secondary open circuit shall not be allowed, and the secondary outlet S2 shall be grounded.Rated operation voltage AC 0.66kV and Rated frequency 50-60Hz.Used in place without direct rain and snow,without severe pollution and acute shock.

diagram-of-akh-0.66-iii-series-current-transformer

Benefits of AKH-0.66/III Series Current Transformer

 Clamshell design easy to view wiring

• Beautiful shape easy wiring

• High accurancy with CE standard

 Suitable for busbar or cable

Use of AKH-0.66/III Series Current Transformer

• Used for internal measurement in industrial and mining enterprises

• Measure 1-3 busbar or cable in the power distribution room

• Convert the large current at the primary side to 5A or 1A, connect to energy meter

• When using a current transformer, the secondary open circuit is not allowed, and the secondary outlet S2 should be grounded


  • Previous:
  • Next:

  • Acrel AKH-0.66/II Series Current Transformer

    Technical Parameters

    Shape Specification Rated current ratio (A) Accuracy degree and corresponding rated load(VA) Straight- through tums Bus spec(mm)/number Installation
    0.2
    0.5
     60III 60III 200-300/5(1) 2.5 60×10/1-3 E
    400/5(1) 5
    1
    500-800/5(1) 10
    1
    1000/5(1)  10
    1
    1200-1500/5(1)  15
    1
    2000/5(1)  20
    1
    2500/5(1) 30
    1
    80III  80III  300-400/5(1) 5 1  80×10/1-3
    500-800/5(1) 10 1
    1000/5(1) 10 1
    1200-1500/5(1) 15 1
    2000/5(1) 20 1
    2500-3000/5(1)  30 1
     100III 100III  600-800/5(1) 10 1 100×10/1─3
    1000/5(1) 10 1
     1200-1500/5(1) 15 1
    2000/5(1) 20 1
    2500-5000/5(1) 30 1
     130III 130III 2000/5(1) 20 1 130×10/1-3
    125×10/1-3
    2500-6300/5(1) 30 1

     

     

     