Acrel ALP500 Low-voltage Protection Measurement and Control Relay

Acrel ALP500 Low-voltage Protection Measurement and Control Relay

● Integrate leakage, overload and earth fault protection

● Comprehensive protection functions

● Fault recording

● 4-way DO

● Harmonic monitoring

● Temperature measurement

● AC85-265V/DC100-300V power supply

 


Product Detail

Technical Parameters

Product Tags

Acrel ALP500 Low-voltage Protection Measurement and Control Relay

General

Acrel ALP500 low-voltage protection measurement and control device (hereinafter referred to as low-voltage protection device) is suitable for low-voltage power distribution circuit with rated voltage to AC660V , integrating power monitoring, feeder protection, opening and closing control, communication networking, node temperature measurement, operation and maintenance management and other functions. It has various protection functions such as inverse time overcurrent, three-stage overcurrent, overpower, zero sequence overcurrent, undervoltage, overvoltage, unbalance (voltage, current), neutral line overcurrent, and leakage current. Different communication modules can be selected to meet the needs of on-site communication.
The product adopts embedded installation and consists of a main body, a transformer and optional functional modules.

Application Scenario

ard alp_副本

Dimension of Current Transformer

图片4

Outline and Dimension

图片1
图片2
图片3

  • Previous:
  • Next:

  • Acrel ALP500 Low-voltage Protection Measurement and Control Relay

    Additional Functions

    Additional Functions

    Code Name

    Additional Functions

    Code Name

    2-63 harmonic voltage and current

    H

    Waveform record

    WR

    communication module

    (choose one)

    1way PROFIBUS DPV0communication

    CP

    Leakage Protection

    L

    2way PROFIBUS DPV0communication

    2CP

    Metering module

    S

    Ethernet communication (MODBUS TCP protocol)

    MCE

    1way 4-20mA Transmission Output

    M1

    4G

    4G

    2way 4-20mA

    Transmission Output

    M2

    Lora

    LORA

    Switch module

    MD

     Technical Parameters

    Technical Parameters

    Technical Indicators

    Auxiliary power Support AC 85-265V/DC 100-300V Wide range power input
    Rated Voltage AC 380V / 660V50Hz / 60Hz
    Rated Current 1 (0.5A-6300A) XXX/1Transformer with external current transformer

     

    5 (0.5A-6300A) XXX/5Transformer with external current transformer
    25(6A-25A) external current transformer
    100(25A-100A)
    Accuracy Protection

    Accuracy

    3-phase Current 1.0 Class
    3-phase Voltage 0.5 Class
    PowerElectrical Energy 2.5 Class
    Measuring

    Accuracy

    3-phase CurrentVoltage 0.5 Class
    Active Power

    Electrical Energy

    0.5 Class
    Reactive Power

    Electrical Energy

    1.0 Class
    Relay output

    contact capacity

    Standard configuration

    4 channels

    resistive loadAC250V/10A
    Optional 3 channels
    Switch Quantity Input Standard configuration

    4 channels

    passive dry junction

    Optional active DC110VDC220VAC220V input
    Optional 10 channels

    passive dry junction

     Communication Standard configuration 2 way MODBUS RTU Communication
    OptionalChoose one 1 way MODBUS-TCP
    1 way PROFIBUS-DPV0
    2 way PROFIBUS-DPV0
    1 way 4G communication
    1 way Lora communication
    Application Environment Working Temperature -10ºC55ºC
    Storage temperature -25ºC70ºC
    Relative humidity ≤95No condensation, no corrosive gas
    Altitude ≤2000m
    pollution level 3 Class
    Protection Grade Main Body IP54Additional function modules IP20
    Installation Type III Class

     

     

     

     

     

     

     