Acrel ALP500 Low-voltage Protection Measurement and Control Relay
Acrel ALP500 Low-voltage Protection Measurement and Control Relay
General
The product adopts embedded installation and consists of a main body, a transformer and optional functional modules.
Application Scenario
Dimension of Current Transformer
Outline and Dimension
Acrel ALP500 Low-voltage Protection Measurement and Control Relay
Additional Functions
|
Additional Functions |
Code Name |
Additional Functions |
Code Name |
|
|
2-63 harmonic voltage and current |
H |
Waveform record |
WR |
|
|
communication module (choose one) |
1way PROFIBUS DPV0communication |
CP |
Leakage Protection |
L |
|
2way PROFIBUS DPV0communication |
2CP |
Metering module
|
S |
|
|
Ethernet communication (MODBUS TCP protocol) |
MCE |
1way 4-20mA Transmission Output |
M1 |
|
|
4G |
4G |
2way 4-20mA Transmission Output |
M2 |
|
|
Lora |
LORA |
Switch module |
MD |
|
|
Technical Parameters |
Technical Indicators |
||
| Auxiliary power | Support AC 85-265V/DC 100-300V Wide range power input | ||
| Rated Voltage | AC 380V / 660V,50Hz / 60Hz | ||
| Rated Current | 1 (0.5A-6300A) | XXX/1Transformer with external current transformer
|
|
| 5 (0.5A-6300A) | XXX/5Transformer with external current transformer | ||
| 25(6A-25A) | external current transformer | ||
| 100(25A-100A) | |||
| Accuracy | Protection
Accuracy |
3-phase Current | 1.0 Class |
| 3-phase Voltage | 0.5 Class | ||
| Power,Electrical Energy | 2.5 Class | ||
| Measuring
Accuracy |
3-phase Current、Voltage | 0.5 Class | |
| Active Power,
Electrical Energy |
0.5 Class | ||
| Reactive Power,
Electrical Energy |
1.0 Class | ||
| Relay output
contact capacity |
Standard configuration
4 channels |
resistive load、AC250V/10A | |
| Optional 3 channels | |||
| Switch Quantity Input | Standard configuration
4 channels passive dry junction |
Optional active DC110V、DC220V、AC220V input | |
| Optional 10 channels
passive dry junction |
|||
| Communication | Standard configuration | 2 way MODBUS RTU Communication | |
| Optional(Choose one) | 1 way MODBUS-TCP | ||
| 1 way PROFIBUS-DPV0 | |||
| 2 way PROFIBUS-DPV0 | |||
| 1 way 4G communication | |||
| 1 way Lora communication | |||
| Application Environment | Working Temperature | -10ºC~55ºC | |
| Storage temperature | -25ºC~70ºC | ||
| Relative humidity | ≤95﹪No condensation, no corrosive gas | ||
| Altitude | ≤2000m | ||
| pollution level | 3 Class | ||
| Protection Grade | Main Body IP54,Additional function modules IP20 | ||
| Installation Type | III Class | ||