Acrel AM5SE-IS Anti-islanding Protection Relay for Renewable Energy EMS

Acrel AM5SE-IS Anti-islanding Protection Relay for Renewable Energy EMS

 

● Zero sequence overvoltage protection;

● Reverse power protection;

● Frequency protection;

● Non-electricity protection;

● Independent operation circuit, can adapt to 0.25A-5A switch tripping and closing current;

● 2-way RS485 serial communication interface, support Modbus-RTU, IEC60870-5-103 protocol;

● 2 Ethernet ports, supporting TCP Modbus-RTU and TCP IEC60870-5-103 protocols;

● IRIG-B format time synchronization


Product Detail

Technical Parameters

Function

Product Tags

Acrel AM5SE-IS Anti-islanding Protection Relay for Renewable Energy EMS

General

AM5SE-IS anti-islanding protection device is mainly suitable for new energy grid-connected power supply systems such as 35kV, 10kV and low-voltage 380V photovoltaic power generation and gas power generation. When the island phenomenon occurs, the grid connection point can be quickly cut off, so that the station can be quickly separated from the grid side, ensuring the safety of the entire power station and related maintenance personnel.

.

Function of AM5SE-IS Anti-islanding Protection Relay for Renewable Energy EMS

AM5SE-IS Function
AM5 - Function - 2

Wiring

AM5SE-IS Wiring

Front Panel

AM5SE - panel

Dimension

AM5SE - Dimension

Network

AM5SE - Typical connection

FAQ of AM5 Middle Voltage Protection Relay

How to set the CT and PT ratio of the protection device?

The protection device can set the CT and PT ratio through the fixed value menu. For example, the current transformer is 75/5 and the voltage transformer is 10/0.1, then the CT ratio is set to 15 and the PT ratio is set to 100.

For AM5, if you want to place a single circuit protection and transformer protection, how to distinguish the model?

AM5-F is suitable for line protection and transformer protection.No need to distinguish between models when placing orders

When the voltage is three-phase three-wire system, does the current have to be connected with 2CT?

The voltage wiring mode and current wiring mode of the protection device can be set independently, and can be connected freely.

How to confirm whether the anti-trip function is configured?

If the circuit breaker is equipped with anti-trip, the device does not must be equipped with anti-trip; if the circuit

breaker does not have anti-trip, you need to configure the AM5-FT anti-trip module. (If DC48V is selected as the

operating power supply, the anti-trip box is not optional, and the circuit breaker must be equipped with anti-trip

function; if you choose AC anti-trip, please note that AC and DC general anti-tripping)

 

How to purchase suitable protection devices?

Before ordering, it is recommended to consult related engineers, select the appropriate protection model,

and then fill in the corresponding selection table, and place the order after confirmation by the engineers.

 


  • Previous:
  • Next:

  • Acrel AM5SE-IS Anti-islanding Protection Relay for Renewable Energy EMS

    Technical Parameters

    CharacteristicsVersion

    AM5SE-F,AM5SE-T,AM5SE-M,AM5SE-C,

    AM5SE-B,AM5SE-D2,AM5SE-D3,

    AM5SE-TB,AM5SE-MD

    AM5SE-UB, AM5SE-IS, AM5SE-FE, AM5SE-FA,AM5SE-K

    Power Supply

    Rated voltage

    AC/DC 110V or AC/DC 220V

    Range

    Rated voltage × (1±20%)

    Burden

    ≤15 VA

    PT Inputs

    Rated value

    AC 100V or V

    AC 380V or 220V

    PT rated secondary range

    0.1V120V

    0.1V ~ 456V

    Accuracy

    0.5S

    Burden

    0.5VA (each phase)

    Voltage withstand

    Continuous: 1.2 Un

    10s: 2 Un

    Phase CT Inputs (Protection Current)

    CT rated secondary range

    AC 5A or 1A

    Dynamic

    20 × CT rated current

    Accuracy

    0.5S

    Burden

    0.5VA (each phase)

    Thermal withstand

    Continuous: 2 In

    1s: 40 In

    Phase CT Inputs (Measurement Current)

    CT rated secondary range

    AC 5A or 1A

    Dynamic

    1.5 × CT rated current

    Accuracy

    0.5S

    Burden

    0.5VA (each phase)

    Thermal withstand

    Continuous: 1.5 In

    1s: 4 In

    Frequency

    Rated frequency

    50Hz or 60Hz

    Frequency range

    40 ~ 70Hz

    Accuracy

    ±0.1Hz

     Digital Inputs

    Operating nominal voltage

    AC/DC 110V or AC/DC 220V

    Voltage threshold

    70% of nominal voltage

    Reset threshold

    55% of nominal voltage

    Burden

     ≤ 1W (each phase) (DC220V)

    Digital Outputs

    Make and carry

    ≥ 10000 operations

    Making capacity

     ≥ 1000W, L / R = 40ms

    Continuous current

    ≥ 5A

    Short duration carry current

    ≥ 30A for 200ms

    Breaking capacity

    ≥ 30W, L/R = 40ms

    Characteristics Accuracy Resolution Disengaging ratio
    Voltage ±3% 0.001V 0.95 and 1.05
    Current ±3% 0.001A 0.95 and 1.05
    Frequency ±0.02Hz 0.001Hz
    Operation delay|t>(DT) 40ms or ±2% setting value 0.001s -
    Operation delay|t>(IDMT) 40ms or ±5% setting value 0.001s -
    Characteristics Standard Level/Class
    Radiated emission IEC-60255-26:2023——5.1

    A

    Conducted emission IEC-60255-26:2023——5.2

    A

    Radiated radio frequency fields IEC-60255-26:2023

    A

    Electrostatic discharge IEC-60255-26:2023——6.1

    B

    Conducted radio frequency disturbance IEC-60255-26:2023——6.2-6.5

    A

    Fast transient bursts IEC-60255-26:2023——6.2-6.5 B
    Slow damped oscillatory waves IEC-60255-26:2023——6.2-6.4

    B

    Surges IEC-60255-26:2023——6.2-6.4 B
    Voltage dips and short interruptions test(AC or DC) IEC-60255-26:2023——6.2

    A/C

    Magnetic field at power frequency IEC-60255-26:2023——6.1

    B

     

     

    Acrel AM5SE Protection Relay for Renewable Energy EMS

    Functions

    Analogue inputs

    AM5SE

    -F

    -T

    -M

    -C

    -MD

    -D2

    -D3

    -TB

    -IS

    -FE

    -FA

    -B

    -K

    -UB

    -FD

    Input current

    8

    8

    8

    8

    9

    9

    9

    8

    6

    8

    8

    8

    8

    0

    /

    Input voltage

    6

    4

    4

    4

    4

    4

    4

    4

    8

    6

    6

    6

    6

    8

    /

    Digital

    -F

    -T

    -M

    -C

    -MD

    -D2

    -D3

    -TB

    -IS

    -FE

    -FA

    -B

    -K

    -UB

    -FD

    Digital Input

    20

    20

    20

    20

    20

    20

    20

    20

    20

    20

    20

    20

    20

    20

    12

    Digital Output

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    64

    Rear port

    -F

    -T

    -M

    -C

    -MD

    -D2

    -D3

    -TB

    -IS

    -FE

    -FA

    -B

    -K

    -UB

    -FD

    RS485 (2 ports)

    Ethernet(2 ports)

    USB(1 port)

    Protocols

    -F

    -T

    -M

    -C

    -MD

    -D2

    -D3

    -TB

    -IS

    -FE

    -FA

    -B

    -K

    -UB

    -FD

    Modbus Serial

    Modbus over Ethernet

    IEC 60870-5-103

    TCP IEC 60870-5-103

    IEC 60870-5-101

    Measurement

    -F

    -T

    -M

    -C

    -MD

    -D2

    -D3

    -TB

    -IS

    -FE

    -FA

    -B

    -K

    -UB

    -FD

    4-20mA analog output

    Electric parameter

    U、IPQPFFrEpEqEs

    U、I

    UFr

    Logs and Records

    -F

    -T

    -M

    -C

    -MD

    -D2

    -D3

    -TB

    -IS

    -FE

    -FA

    -B

    -K

    -UB

    -FD

    Fault recorder

    Number of circuit breaker trip and close

    Sequence of event record

    Monitoring function

    -F

    -T

    -M

    -C

    -MD

    -D2

    -D3

    -TB

    -IS

    -FE

    -FA

    -B

    -K

    -UB

    -FD

    Trip-and-Close Circuit Supervision

    Remote control

    Others

    -F

    -T

    -M

    -C

    -MD

    -D2

    -D3

    -TB

    -IS

    -FE

    -FA

    -B

    -K

    -UB

    -FD

    GPS

    Protection Function

    -F

    -T

    -M

    -C

    -MD

    -D2

    -D3

    -TB

    -IS

    -FE

    -FA

    -B

    -K

    -UB

    -FD

    3 stages directional overcurrent

    (with voltage dependant)[ANSI 67]

    3 stages overcurrent

    (with composite voltage blocking)[ANSI 50/51]

    Differential protection with ratio restraining[ANSI 87]

    Instantaneous Differential protection[ANSI 87]

    Motor overcurrent(motor start,motor run,2 stages)

     Overcurrent (2 stages) [ANSI 50/51]

    Overcurrent IDMT [ANSI 51N]

    Bus charge

    Protection Function

    -F

    -T

    -M

    -C

    -MD

    -D2

    -D3

    -TB

    -IS

    -FE

    -FA

    -B

    -K

    -UB

    -FD

    Bus tie protection and standby power automatic switch

    2 stages Directional earth fault

    [ANSI 67N]

    2 stages earth fault [ANSI 50N/51N]

    Earth fault IDMT[ANSI 50N/51N]

    Clearance earth fault protection(2 stages)

    Negative sequence overcurrent (2 stages)[ANSI 46]

    Negative sequence overcurrent IDMT[ANSI 46]

    Overload [ANSI 49F]

    Starting air-cooled water chiller

    On-load tap charge lock-out

    Undervoltage (trip)[ANSI 27]

    Undervoltage (alarm)[ANSI 27]

    Capacitor undervoltage(trip)

    Loss of voltage (trip)

    Loss of voltage (alarm)

    Overvoltage protection[ANSI 59]

    Residual voltage protection(trip)[ANSI 59N]

    Residual voltage protection(alarm)[ANSI 59N]

    PT supervision[ANSI 60]

    Unbalance voltage[ANSI 60]

    Unbalance current[ANSI 60]

    Motor starting time-out[ANSI 48]

    CT supervision[ANSI 60]

    Three phase Auto-reclose[ANSI 79]

    Thermal overload protection[ANSI 49M]

    Locked rotor[ANSI 51LR]

    FC block[ANSI 86]

    Post-accelerated overcurrent

    Under frequency[ANSI 81U]

    Over frequency[ANSI 81O]

    Incorrect phase sequence

    Voltage Phase loss protection

    Directional power protection[ANSI 32]

    Power recovery protection

    Under power protection

    Non-electricity

    PT supervision and parallel connection

     Synchro-check[ANSI 25]

    Rate of change of frequency[ANSI 81R]

    Trip-and-Close Circuit Supervision(alarm)

    Protection Function

    -F

    -T

    -M

    -C

    -MD

    -D2

    -D3

    -TB

    -IS

    -FE

    -FA

    -B

    -K

    -UB

    -FD

    Auto-close with voltage recovery

    PT harmonic elimination

    Overhaul-lockout[ANSI 86]