Acrel ADW600 Multi Circuits Power Metering Module

Acrel ADW600 Multi Circuits Power Metering Module

● Three-Phase Energy Monitoring System

● Multi-Circuit Current Measurement Solution

● Rated Current 5A/100A/400A/600A

● 4DI/2DO (Passive)

● Industrial & Commercial Energy Management

● EV Charging And Distribution Monitoring

 


Product Detail

Technical Parameters

Product Tags

Acrel ADW600 Multi Circuits Power Metering Module

General

Acrel  ADW600 is an advanced IoT multi-circuit power metering module for modern low-voltage power distribution systems. Capable of three-phase energy monitoring, it accurately measures voltage, current, power and energy consumption of multiple circuits. Featuring a modular structure including voltage, current, relay output, temperature measurement and leakage current modules interconnected via Ethernet, it supports flexible module combinations. Compact and easy to install, it delivers high-precision metering alongside diverse communication interfaces. Powered by IoT architecture, it enables real-time data transmission, remote management and data analysis.

Widely deployed in EV charging stations, data centers, commercial buildings and power distribution facilities, it fits multi-circuit metering scenarios and low-voltage grid power renovation projects. Offering comprehensive energy data and operational visibility, the ADW600 helps users boost energy efficiency, cut operational costs and strengthen power system safety, serving as a dependable choice for next-gen smart energy monitoring and IoT power management.

Application Scenario

ADW600 Application Scenario_副本

Wiring Diagram

ADW600 - connection - 1_副本

Outline and Dimension

1-2603231534504A

  • Previous:
  • Next:

  • Acrel ADW600 Multi Circuits Power Metering Module

    Functions

    Model

    Function

    ADW600-M

    Data collection and remote transmission

    4G / Ethernet / WIFI)

    ADW600-U

    Voltage measurement and sampling

    ADW600-I

    Active power metering (positive and reverse),

    Quadrant reactive power energy

    Voltage, current, power factor, frequency, active power, reactive power, apparent power

    Total harmonic content, sub-harmonic content (2nd to 31st)

    Pulse Output of active energy

    ADW600-K

    4DI、2DO

    ADW600-TL

    12 channels of temperature measurement, 4 channels of residual current measurement

     Technical Parameters
    ADW600-U Rated Voltage 3×57.7/100V,3×220/380V,3×100V, 3×380V
    Voltage Accuracy 0.5%
    Frequency 45-65Hz
    Power Consumption <0.5VA (each phase)
    ADW600-I Input Current D10:0.03-0.15(6)A,D16:0.8-2(100)A,D24:3.2-8(400)A,D36:4.8-12(600)A
    Accuracy of Active Energy B Class
    Pulse width of energy 80±20ms
    Active Energy Pulse Constant D10:6400imp/kWhD16:400imp/kWhD24:100imp/kWhD36:60imp/kWh
    Power Consumption <1VA (each phase)
    ADW600-K DI 4-channel passive input, built-in DC12V power supply
    DO 2-channel passive output, capacity AC230V/DC30V, 3A
    ADW600-TL Temperature Measurement 12-channel temperature measurement, accuracy:±2℃, with 12 temperature measurement leads.
    Residual Current Measurement 4-channel residual current measurement, input range up to 1mA, accuracy 1%, residual current transformer must be purchased separately
    Temperature Range Operating temperature

    -25~55Storage temperature-40~70Humidity≤95%

    (without condensation)Altitude<2000m